Symptoms

 

Job Ticket Processors (JTPs) disappear from Prinergy Administrator. If the primary server is restarted, the JTPs reappear.


Cause

  Prinergy secondary server(s) and renderstation(s) are not on the network when Prinergy is started on the primary server. The server name will be listed in the server pane but no JTPs are listed for the missing server.

Another possible cause is anomalous network behaviour where the primary cannot communicate with a secondary server or renderstation. Multi-homing can also cause this problem.


Solution

 

Ensure all servers are running and on the network before starting Prinergy on the primary server.

This problem has been fixed in Prinergy 2.1