Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Workshop clients fail to connect, unrecoverable Corba error.


Product

  Prinergy Connect 2.1 Level 0; Prinergy Direct 2.1 Level 0; Prinergy Access 2.1 Level 0; Prinergy Powerpack 2.1 Level 0; Prinergy Satellite

Platform

 

Operating system

 


Error

 

"Unrecoverable Corba error occurred. [1101020]"


Symptoms

 

Workshop client fails with corba error when logging in.

Workshop on the Primary is not affected.

There no errors in the diagnostic logs to indicate there's a problem.


Cause

  A network configuration error causing corba communication failure.

Solution

 

Check the primary server and remove the DNS suffix or Update to 2.1.0.6

Permanent fix:


See also

 


Keywords

 

workshop


Technical contact(s)
 

Simon Chen;Shelley Hendricks

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.