Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy Workshop login fails on a Macintosh client, with error "Unrecoverable Corba error occurred" [1101020]"


Product

  Prinergy Connect 2.1 Level 6; Prinergy Direct 2.1 Level 6; Prinergy Access 2.1 Level 6; Prinergy Powerpack 2.1 Level 6; Prinergy Satellite

Platform

 

Operating system

 


Error

 

Error Message when logging on:

Login Failed [1101020]

Unrecoverable Corba error occurred. [1101020]

Error Message when attempting update:

Confirm Update [1088077]

Workshop is unable to connect to server <servername> to determine the version of Workshop available there. An Update may not be required. [1088077]


Symptoms

 

Unable to log in to the Primary server from a Macintosh Prinergy Workshop client after updating to Prinergy 2.1.0.6


Cause

  The Macintosh client was not able to resolve the host name passed back by Prinergy. A Prinergy configuration script was not able to modify a registry value due to an unusual user account configuration.

Solution

 

A temporary solution is to create a Macintosh hosts file with SimpleText. Add the Prinergy Primary and load the host file in the TCP/IP settings.

Host file format:<ServerName> CNAME <ServerName>.<suffix>

For a permanent solution, contact the Creo Response Center to correct the registry setting. Please reference KB article number: SCHN-0000290.

Permanent fix:


See also

 


Keywords

 

orbix, workshop


Technical contact(s)
 

Simon Chen

Submitted by
 

Simon Chen