Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.1 Level 6; Prinergy Direct 2.1 Level 6; Prinergy Access 2.1 Level 6; Prinergy Powerpack 2.1 Level 6; Prinergy Satellite | |
Platform |
||
Operating system |
||
|
|
||
Error |
Error Message when logging on: Login Failed [1101020] Unrecoverable Corba error occurred. [1101020] Error Message when attempting update: Confirm Update [1088077] Workshop is unable to connect to server <servername> to determine the version of Workshop available there. An Update may not be required. [1088077] |
|
|
|
||
Symptoms |
Unable to login to the Primary server from a Macintosh workshop after update to 2.1.0.6 |
|
|
|
||
Cause |
Orbicus is passing back a hostname and the Macintosh is not able to resolve the it. It should be passing back an IP address. | |
|
|
||
Solution |
At Prinergy startup, checknetworkconfig script is run to set the orbicus configuration in the registry to the current IP address. For whatever reason this is not working. Modify the following registry values :
HKLM\Software\OOC\Properties\ooc\imr admin_endpoint forward_endpoin slave_endpoint KLM\Software\OOC\Properties\ooc\oa endpoint Change the host name to IP address. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
networking, workshop |
|
|
|
||
Technical contact(s) |
Simon Chen |
|
Submitted by |
Simon Chen |
|
Date submitted |
29 Nov 2002 |
|