Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Treat Input files as Flats behaves differently in Prinergy 2.1 than in Prinergy 2.0.7


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 


Symptoms

 

A shift is applied to the assigned subpage to align the lower left corner of the trim box with the lower left corner of the imposition plan. The way this shift is calculated is different in Prinergy 2.1 and Prinergy 2.0.7, resulting in different output between the two versions of Prinergy.


Cause

 

Solution

 

1. Distill the PS without Prinergy Distiller Plug-in, then refine.

2. Change the geometry using geometry editor and re-refine (not an option if you are using Prinergy Direct).

Permanent fix:


See also

 


Keywords

 

Geometry, output, PDF


Technical contact(s)
 

James Bredenhof

Submitted by
 

James Bredenhof

Date submitted
 

18 Feb 2003