Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 ; Prinergy Satellite | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
In Prinergy 2.2.1.0 and lower, Prinergy had a "composite print warning" which would appear when RIPping the DCS Vector in composite mode. This warning message was removed in 2.2.1.1 and higher because it interfered with some 3rd party OPI and preflight solutions. However, there might still be cases where the "composite print warning" is desired. |
|
|
|
||
Cause |
||
|
|
||
Solution |
In the Registry, under HKLM\SOFTWARE\Creo\Araxi\Settings\Default\DCSV\JTPName\DCSCompositePrintWarning, set value to 1. Restart Vector JTPs from Prinergy Administrator. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
vector output |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
James Bredenhof |
|
Date submitted |
17 Nov 2003 |
|