Symptoms |
DigiCap Keepaway amount is wrong on output. Output was sent with Keepaway of N. Immediately after, Keepaway value changed to M in Process Plan and new output sent while first output still processing. When first output is examined, Keepaway value is M instead of N. |
|
|
|
||
Cause |
There is a subtle problem in the way JT parameters were read in 2.2.1.4. When two tasks launched -- first with Keepaway of N, second with Keepaway of M -- the output from first task would have Keepaway of M. The class variable was overwritten with the second value before Prinergy had finished processing the first task completely. | |
|
|
||
Solution |
Before sending new outputs with changed DigiCap Keepaway values, ensure that all previous outputs have completed processing. This problem will be fixed in the Prinergy 2.2.1.5 release. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
output, plate, Powerpack, screening |
|
|
|
||