Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 1.0; Prinergy 1.1; Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
running backup gives an exception indicating that it is trying to loop over a non-sequence object |
|
|
|
||
Symptoms |
backup of oracle fails |
|
|
|
||
Cause |
the python script which reads the initcreo.ora parameters does not recognize comments. As a result it is returning the comments with the value. For example, it would return "E:\ORANT\ORACLE\ARCHIVEDLOGFILES #some comment" rather than E:\ORANT\ORACLE\ARCHIVEDLOGFILES |
|
|
|
||
Solution |
Ensure that all comments in the initcre.ora file are on their own lines. For example the initcreo.ora should say : #Added by Prinergy log_archive_dest = E:\ORANT\ORACLE\ARCHIVEDLOGFILES rather than log_archive_dest = E:\ORANT\ORACLE\ARCHIVEDLOGFILES # added by prinergy Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
backup, Connect, oracle |
|
|
|
||
Technical contact(s) |
Stan Yoshida |
|
Submitted by |
Shelley Hendricks |
|
Date submitted |
09 May 2002 |
|