Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
2.3.1.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
All JTPs shut down when using CT/LW output or Veris connectivity |
|
|
|
||
Cause |
If certain CT/LW Output or Veris process plans were used, DASS would get an access violation and shutdown all JTPs. | |
|
|
||
Solution |
Fixed in Prinergy 2.3.1.2. Upgrade to 2.3.1.2. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
DASS, JTP, proofing |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
James Bredenhof |
|
Date submitted |