When you create a new process template for the Kodak Veris digital proofer or the Kodak Matchprint® Inkjet proofer, or you add a new Kodak proofer, the name of the proofing device is not listed on the Devices tab of the process template. The media size and proofer templates also do not appear correctly on the Layout tab. |
|
|
|
||
Cause |
The problem may be caused by any of the following possible causes: Cause 1: The printer JTPs on the Prinergy primary server have a different list of available Kodak proofers than the printer JTPs on the secondary servers. This occurs because when proofers are added or removed in Prinergy Administrator, the only registry updated is the one on the local Prinergy server. (See Solution 1.) Cause 2: The DNS (domain name server) name is configured incorrectly. (See Solution 2.) Cause 3: A proofing pool is empty. (See Solution 3.) Cause 4: Prinergy Administrator contains a host name that is not Kodak Proofing Software (KPS). (See Solution 4.) Cause 5: The Windows Firewall software is running on the proofer server (KPS version 3.1.x only). See Solution 5.) Cause 6: One or more of the proofers listed in Prinergy Administrator does not exist. (See Solution 6.) |
|
|
|
||
Solution |
Solution 2: Ensure that the hosts files contain correct DNS names: Solution 3: Either remove the empty pool or add JTPs to the pool: Solution 4: Remove the non-KPS host name from the Prinergy server (see Solution 2), and then restart the proofer JTPs. (Right-click each JTP, select Stop JTP, and then Start JTP.) Solution 5: (KPS version 3.1.x only) Shut down the Windows Firewall software on the proofer computer. For information, see the Windows Firewall documentation. Solution 6: Remove all proofers, and then add them back from the list of available servers: Note: If the proofer that you want doesn't appear in the list, something is preventing the UDP network packets from being transferred between the controller and the Prinergy server. Try adding the proofer by name, using the format ControllerName/ProoferName. You must type the name correctly.
|
|
|
|
||
Keywords |
process templates, proofing |
|
|
|
||
Technical contact(s) |
Ken Boyle | |
Submitted by |
Ken Lew |
|
Date submitted |
26 Sep 2006 |
|