Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


PPU complains when the parameter in -dir is a file instead of a folder


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

The 2.0.5.0 PPU message is:

ERROR: Exception in process 984, thread 1644

Traceback (innermost last):

File "ppu.py", line 242, in run

patchList = self.engine.CheckForNewUpdates( self.opt.patchdir )

File "e:\temp\~ppu.0\ppuengine.py", line 227, in CheckForNewUpdates

updateDirList = os.listdir( updateDir )

OSError: [Errno 267] Unknown error


Cause

  When the parameter that should identify a folder name in the "-dir" mode points to a file name, PPU doesn't write a clear message to indicate the exact cause.


Solution

 

Use the "-dir" command followed by the folder name that contains the update files to be installed.

Permanent fix:


See also

 


Keywords

 

ppu


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.