Error |
||
|
|
||
Symptoms |
Signapack launches interactively from within Prinergy, but when a job ticket is created in Signapack to be imported into Prinergy, it hangs on import. |
|
|
|
||
Cause |
If Signapack is installed onto a drive other than the C: drive, it cannot find a temp folder that is hard coded to be the C: drive in the file: Signation6\signastation6.app\resources\scripts\NewLandingPad # show parameters in a file echo "NewLandingPad Input Parameters" > C:/temp/NewLandingPadParameters echo 1:$1 >> C:/temp/NewLandingPadParameters echo 2:$2 >> C:/temp/NewLandingPadParameters echo 3:$3 >> C:/temp/NewLandingPadParameters |
|
|
|
||
Solution |
There are a couple of workarounds: 1. Create a C:\temp folder. or 2. Change the drive letters in the NewLandingPad file to the system drive. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
job ticket, Signastation-Signapack |
|
|
|
||
Technical contact(s) |
Sandy Wong |
|
Submitted by |
Sandy Wong |
|