Error in DiagView - [INVALIDPOSITION] Invalid position within RWDBStoredProc...


Product

  Prinergy 1.1; Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

An error similar to the following appears in DiagView:

A general database failure has occured: [INVALIDPOSITION] Invalid position within RWDBStoredProc DBCS_GetLatestSchemaVersion.

The stored procedure name (DBCS_GetLatestSchemaVersion in this example) may vary.

Depending upon the stored procedure at fault, Prinergy may exhibit different symptoms, such as failure to import impositions, display history, or register files.


Cause

  The stored procedure did not compile.

The status of the procedure can be seen by issuing an SQL query similar to this:

select status from user_objects where object_name like 'DBCS_GetLatestSchemaVersion';

Replace the stored procedure name 'DBCS_GetLatestSchemaVersion' with the stored procedure in error.

The status will show 'INVALID' if the stored procedure did not compile.


Solution

 

Recompile all objects in the Prinergy database with the status of INVALID.

In Prinergy 1.1 systems:

1) Start PLUS80 in a command prompt window.

D:\> PLUS80 araxi_1_0_12/araxi

2) In PLUS80, execute the stored procedure DBCS_CompileObjects

SQL> execute dbcs_compileobjects;

3) Exit PLUS80

SQL> exit

In Prinergy 2.0 systems:

1) Start SQLPLUS in a command prompt window.

D:\> SQLPLUS prinergy/araxi

2) In SQLPLUS, execute the stored procedure DBCS_CompileObjects

SQL> execute dbcs_compileobjects;

3) Exit SQLPLUS.