Symptoms

 

The NT Resource Kit utility 'PrintMig.exe' hangs and shows the status of 'Starting Spooler' and 'Spooler Running'.


Cause

  The folder that the PrintMig utility is installed in contains spaces.

The PrintMig utility is used in the Prinergy 1.1 Re-Hosting document (72-3494A-A-PR01). PrintMig is an NT 4 Resource Kit utility that backs up and restores the NT printer configuration. This utility is only compatible with Windows NT; it is not Windows 2000 compatible.


Solution

 

Kill the PrintMig utility using Task Manager.

Rename the folder to not contain spaces.

Permanent fix:


See also

 