Error: Invalid position within RWDBStoredProc DBCS_ItemInTaskTemp_ProcSte_S after installing patch 128


Product

  Prinergy 1.1

Platform

 

Operating system

 


Error

 


Symptoms

 

The following error message appears in DiagView when trying to output after patch 128 is installed:

A general database failure has occured: [INVALIDPOSITION] Invalid position within RWDBStoredProc DBCS_ItemInTaskTemp_ProcSte_S


Cause

  Patch 128 replaces PJobD (job daemon) and this newer version of PJobD is dependent upon updated stored procedures in the database installed by patch 98.

Solution

 

Un-install all the most recent patches to allow the installation of patch 98. Install patch 98 and re-install all the newer patches.

Permanent fix:


See also

 


Keywords

 

output, patches


Technical contact(s)
 

Simon Chen

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.