System backup fails with the error indicating the AraxiVolume well-known share could not be converted to local path.


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

System backup fails with the error:

Error: The AraxiVolume_<server name>_<drive letter> well known share could not be converted to a local path.

The backup completes but the completion time is not updated in UADM.


Cause

  The backup script is looking for the local path of the AraxiVolume share in the LanmanServer\Shares registry key.

A typical share will contain these values:

CSCFlags=0

MaxUses=4294967295

Path=J:\

Permissions=63

Type=0

If the registry is missing the CSCFlags=0 entry, the backup script will fail to get the Path entry.


Solution

 

Add the entry CSCFlags=0 for all for the AraxiVolume share(s) in the LanmanServer\Shares registry key.

1) Start REGEDT32

2) Navigate to HKLM\System\CurrentControlSet\Services\LanmanServer\Shares.

3) Double-click each AraxiVolume share found in the registry key and add the CSCFlags=0 at the top of the list.