Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 ; Prinergy Satellite | |
Platform |
||
Operating system |
||
|
|
||
Error |
E 25Jun02 11:15:52.485-PDT [2864.3200] PASSAT AraxiLab PTaskD.JobTicketSubmissionThread: 3200 TAKS_JobTicketSub.cpp(449): caught exception, class COMN_Exception exception: Supplied path is not a UNC path: E:\TaskServerData\00569\processplan.tpl Z 25Jun02 11:15:52.500-PDT [2864.3200] PASSAT AraxiLab PTaskD.JobTicketSubmissionThread: 3200 TAKS_JobTicketSub.cpp(622): An error occurred while creating the subtasks for this task. The subtask list is incomplete. |
|
|
|
||
Symptoms |
After moving the TaskServerData folder to another drive, proofing tasks immediately fail. |
|
|
|
||
Cause |
When moving the TaskServerData folder to the other drive, a local path was used in the Task Server registry key Default\TAKS\TaskServerDataDirectory. | |
|
|
||
Solution |
Change the registry key Default\TAKS\TaskServerDataDirectory to a UNC path and restart Prinergy. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
proofing, registry |
|
|
|
||
Technical contact(s) |
Stan Yoshida |
|
Submitted by |
Stan Yoshida |
|
Date submitted |
26 Jun 2002 |
|