Dotshop Composer does not list all the screens


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 


Symptoms

 

Some screens such as IS, Diamond, MaxTone, or Megadot do not show up in the Screening Systems list in Dotshop Composer.


Cause

  A JTP with those screens enabled must be installed on the system. Dotshop Composer will only get the list of screens from one of the JTP's.


Solution

 

If you only see Creosettes, and Staccato screens then you will have to create a 512 MB JTP on the system if you wish to see the other screens in Dotshop Composer.

If you only see Creosettes, HQS, RT and Staccato screens, enable the other screens on the 512 MB JTPs and run Dotshop Composer. After the .sif file is created, reset the screens for the JTP's.

Permanent fix:


See also

 


Keywords

 

Dotshop, screening


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

30 Oct 2002