Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Minor update 2.1.0.10 fails to install with error: Cannot create orbacus service NameService.


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 ; Prinergy Satellite

Platform

 

Intel

Operating system

 

Windows 2000


Error

 

ERROR: Update Prinergy Update 2.1.0.10 installation failed! ***

ERROR: Cause: exceptions.Exception Error: Cannot create orbacus service NameService.

Details: exceptions.Exception "Path:" could not be found.

Output: Could not contact IMR


Symptoms

 

The IP address of the server has been changed then minor update 2.1.0.10 is installed. The installation of 2.1.0.10 fails with the error below.


Cause

  The HKLM\Software\OOC\Properties\ooc\imr and HKLM\Software\OOC\Properties\ooc\orb\oa registry keys contain values which reference the IP address of the server. If the IP address has changed, but CheckNetworkConfig has not been run, the registry keys will not be updated with the new IP address. CheckNetworkConfig runs during the startup of Prinergy and will update the Orbacus registry with the new IP address if necessary.

Solution

 

Before installing 2.1.0.10, run %AraxiHome%\CreoAraxi\Bin\CheckNetworkConfig.cmd in a command prompt window. CheckNetworkConfig will update the IP address in the registry to match the machine's IP address.

NOTE: If the server is multi-homed, and the IP address for the network card which connects to the other Prinergy servers is changed, you will have to manually update the HKLM\Software\OOC\Properties\ooc\imr and HKLM\Software\OOC\Properties\ooc\orb\oa registry keys.

To manually update the keys with the new IP address:

1) Start Regedt32

2) Update the following values in HKLM\Software\OOC\Properties\ooc\imr:

- admin_endpoint (REG_SZ)

- forward_endpoint (REG_SZ)

- slave_endpoint (REG_SZ)

3) Update the following value in HKLM\Software\OOC\Properties\ooc\orb\oa:

- end_point (REG_SZ)

Permanent fix:


See also

 


Keywords

 

patches


Technical contact(s)
 

Stan Yoshida