Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy starts then shuts down, Diagview shows error: unable to resolve Name Service System exception `TRANSIENT'


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 ; Prinergy Satellite

Platform

 

Intel

Operating system

 

Windows 2000


Error

 

E 23Jan03 16:28:04.075-PST [1636.1832] YCC9999-999 AraxiLab PCreateJacketOnStart.main CORB_NameService.cpp(116): unable to resolve Name Service System exception `TRANSIENT'

Locality: exception has been received "over the wire"

Completed: no

Minor code: 0x0


Symptoms

 

If Prinergy is started, the majority of the processes will start then immediately stop. Eventually, the Implementation Repository will stop and after that, all remaining processes will stop.


Cause

  The Orbacus configuration is incorrectly configured or has been corrupted. This may be the result of changing the computer name.


Solution

 

Run the OrbacusConfig script to re-configure Orbacus. A link to the OrbacusConfig.cmd script can be found in the See Also section of this workaround.

To run OrbacusConfig.cmd:

1) Open a command prompt window

2) Enter: ORBACUSCONFIG -init

Permanent fix:


See also

 

OrbacusConfig.cmd


Keywords

 

daemon, orbix


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

23 Jan 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.