Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy 2.2.1.3 Administrator on secondaries/rendersation reports dongle error


Product

  2.2.1.3 and 2.2.1.4

Platform

 

Operating system

 


Error

 


Symptoms

 

On secondaries or renderstations running Prinergy 2.2.1.3 or 2.2.1.4, Prinergy Administrator will report "Failed to retrieve Dongle Security Code. The Dongle is missing or is invalid. Please check that an authorized Dongle is properly connected to this server." and "Dongle is Invalid! Please ensure an authorized Dongle is attached to this server."

Prinergy Administrator will continue to run in spite of this message.


Cause

 

Solution

 

If you're REALLY concerned by this message, you can safely retrieve the UADM.exe from the patch restore directory and replace it on the secondaries/rendersation.

-----

Note that there was an anecdotal report that this sort of error message can occur on startup if Prinergy Evo and Prinergy Connect are installed on the same machine. Evo uses a Sentinel USB driver, which blows away the Prinergy Connect parallel driver. Uninstalling the driver and re-installing the Connect driver (from the Client CD) allows the Connect system to start normally

Permanent fix:


See also

 


Keywords

 

administrator, install


Technical contact(s)
 

James Bredenhof

Submitted by
 

James Bredenhof

Date submitted
 

12 Dec 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.