Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Cannot switch to EPM mode on secondary server.


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Intel

Operating system

 

Windows 2000


Error

 

"Orbacus Name Service not updated in registry, VENUS.".


Symptoms

 

Cannot switch to EPM mode on the secondary server. When switch to EPM mode, an pop-up box with the error shown above appears.

This happens if the EPM secondary server has been switched from one primary server to another.


Cause

  The Orbacus registry value OOC\Properties\ooc\orb\service\NameService still points to the old primary server.

Solution

 

Change the registry value OOC\Properties\ooc\orb\service\NameService to point to the current primary server.

Permanent fix:


See also

 


Keywords

 

Emergency Platemaking (EPM)


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

11 Dec 2003