Error |
"Orbacus Name Service not updated in registry, VENUS.". |
|
|
|
||
Symptoms |
Cannot switch to EPM mode on the secondary server. When switch to EPM mode, an pop-up box with the error shown above appears. This happens if the EPM secondary server has been switched from one primary server to another. |
|
|
|
||
Cause |
The Orbacus registry value OOC\Properties\ooc\orb\service\NameService still points to the old primary server. | |
|
|
||
Solution |
Change the registry value OOC\Properties\ooc\orb\service\NameService to point to the current primary server. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
Emergency Platemaking (EPM) |
|
|
|
||
Technical contact(s) |
Stan Yoshida |
|
Submitted by |
Stan Yoshida |
|
Date submitted |
11 Dec 2003 |
|