Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Cannot create jobs in Workshop


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Intel

Operating system

 

Windows 2000


Error

 

Error 1:

No shared volumes were found.[1088023]

Please check the network connection to the shared volume(s).

Error 2:

No suitable job home servers were found.[1088021]

Please check the network connection to the server(s) and make sure that the servers have properly configured shared volumes.


Symptoms

 

When you attempt to create a job in Workshop, you get the errors above in Workshop.

You can open existing job in Workshop but cannot create any new jobs.

There are no errors in Diagview.


Cause

  The registry key HKLM\System\CurrentControlSet\Services\LanmanServer\Shares contains entries for AraxiVolume shares that are not accessible. A "dead" share can exist in the registry if a disk drive is removed from the system before removing the NT share from the drive.

Solution

 

Remove the entry for the "dead" NT share from the registry key HKLM\System\CurrentControlSet\Services\LanmanServer\Shares. You must restart Prinergy after removing the registry value(s) for the dead share(s).

Before removing the entry for the dead share, export the HKLM\System\CurrentControlSet\Services\LanmanServer\Shares registry key first using Regedit.

Permanent fix:


See also

 


Keywords

 

Windows 2000, workshop


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

12 Jan 2004