Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Job export fails to create the export file


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Intel

Operating system

 

Windows 2000


Error

 

Z 05Jul04 15:45:54.050-PDT [5676.3584] PRINERGYPRIMARY ARAXI PTaskD.XCON_Callback TAKS_JobSub.cpp(1435): ImportExportOnPrinergyPrimary:export-job(1): Import/Export: Export file could not be created.


Symptoms

 

Exporting a job fails and reports the error: Export file could not be created.


Cause

  The export path specified in the process plan points to the root of the job folder (%JOB%). The export file should be created within a subfolder of the job.

Solution

 

1. Open the export process plan and change the Export Path parameter from %JOB% to %JOB%\<subfolder>.

2. Change "<subfolder>" to an actual folder name. The export process will create the subfolder if it does not exist.

Permanent fix:


See also

 


Keywords

 

import-export


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

12 Jul 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.