Workshop crashes with IMP_LIMIT error when renaming a job


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1

Platform

 

Intel

Operating system

 

Windows 2000


Error

 

i 19Oct04 10:55:31.421-PDT [2240.4092] YCS3739-1845 ARAXI PMainDirectoryD JCKD_JacketRenamer.cpp(245): Renaming jacket with id 00000000000000000401 to 30415_Red_Rocket

i 19Oct04 10:55:31.453-PDT [2240.4092] YCS3739-1845 ARAXI PMainDirectoryD JCKD_JacketRenamer.cpp(457): Stopped watching hotfolders for job 00000000000000000401

i 19Oct04 10:55:31.453-PDT [2240.4092] YCS3739-1845 ARAXI PMainDirectoryD JCKD_JacketRenamer.cpp(470): Stopped watching hotfolders inside directory \\ycs3739-1845\AraxiVolume_ycs3739-1845_J\Jobs\Red_Rocket

E 19Oct04 10:55:54.328-PDT [2240.4092] YCS3739-1845 ARAXI PMainDirectoryD iJKDR_RenameJobOpImpl.cpp(157): CORBA::SystemException caught:System exception `IMP_LIMIT'

Locality: exception has been received "over the wire"

Completed: no

Minor code: 0x4f4f0002 (can't create new thread)

E 19Oct04 10:55:54.375-PDT [000.000] ycs3739-1845 ARAXI workshop com.creo.araxi.USVW.USVW_eFatalIDL: Unrecoverable Corba error occurred.


Symptoms

 

Workshop consistently crashes with the error IMP_LIMIT when you attempt to rename a job.


Cause

  The registry value HKLM\Software\Creo\Araxi\Settings\Default\System\PrimaryNodeName contains lowercase letters for the computer name.

Solution

 

Change the contents of the registry value HKLM\Software\Creo\Araxi\Settings\Default\System\PrimaryNodeName to uppercase and restart Prinergy.

Permanent fix:


See also

 


Keywords

 

workshop


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

20 Oct 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.