Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Hotfolders are cold


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Intel

Operating system

 

Windows 2000


Error

 


Symptoms

 

All the hotfolders are cold. If you remove and re-add a hotfolder or create a new hotfolder, that hotfolder will work until you restart Prinergy. After restarting Prinergy, all the hotfolders will be cold.

There are no errors in the diag logs from PHotfolderD (SPHF).

The PHotfolderD process will only have 11 threads. Normally PHotfolderD will display informational messages in diag as the threads monitoring the hotfolders are created. In this case, no information messages appear other than that the hotfolder daemon has started.


Cause

  The computer name in the registry key Software\Creo\Araxi\Settings\Default\System\PrimaryNodeName is set to lowercase.

Solution

 

Edit the registry key Software\Creo\Araxi\Settings\Default\System\PrimaryNodeName and set the computer name to uppercase.

Permanent fix:


See also

 


Keywords

 

daemon, hot folders, registry


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Stan Yoshida

Date submitted
 

19 Nov 2004