Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


DigiCap not applied from Final Output Process Plan


Product

  2.2.1.4

Platform

 

Operating system

 


Error

 


Symptoms

 

DigiCap is turned on in Final Output process plan, but Final Output does not have DigiCap applied. No DigiCap information is logged to History.


Cause

  Tag being incorrectly written to Job Ticket from Final Output process plan.

Solution

 

As DigiCap is presently of concern only to flexo customers, who require TIFF Output, Final Output process plans do not have to be used to create final TIFF files.

Use Layout Proof Output process plans to create final TIFF files with DigiCap screening. Layout Proof Output process plans correctly apply DigiCap and log DigiCap information to History logs.

Permanent fix:


See also

 


Keywords

 

output, plate, screening


Technical contact(s)
 

Scott Effler

Submitted by
 

Stephen Zmetana

Date submitted
 

26 Jan 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.