Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Powerpack 2.1 Level 2.2.1.9 | |
Platform |
||
Operating system |
||
|
|
||
Error |
Customers using "ArtPro Direct" workflow. Step and Repeat done in ArtPro using OPI, and PS written thin from ArtPro. PS flat is refined in Prinergy with NormInputConfig to do OPI Bypass. VPS proofs show correct angles, but final plate output results in all screens at same angle. Only with new 3016 RIP, works okay with 3011. |
|
|
|
||
Symptoms |
All colors are screened at same angle on plate. |
|
|
|
||
Cause |
||
|
|
||
Solution |
Write FAT PS from ArtPro and Refine without OPI Bypass. Fixed in 2.2.1.10 and 2.3.1.0. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
OPI, RIP, file formats, output, plate, screening |
|
|
|
||
Technical contact(s) |
Stephen Zmetana |
|
Submitted by |
||
Date submitted |
||