Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


3016 RIP final output screens all colors at same angle, when using ArtPro Thin PS and OPI Bypass.


Product

  Prinergy Powerpack 2.1 Level 2.2.1.9

Platform

 

Operating system

 


Error

 

Customers using "ArtPro Direct" workflow. Step and Repeat done in ArtPro using OPI, and PS written thin from ArtPro. PS flat is refined in Prinergy with NormInputConfig to do OPI Bypass. VPS proofs show correct angles, but final plate output results in all screens at same angle. Only with new 3016 RIP, works okay with 3011.


Symptoms

 

All colors are screened at same angle on plate.


Cause

 

Solution

 

Write FAT PS from ArtPro and Refine without OPI Bypass. Fixed in 2.2.1.10 and 2.3.1.0.

Permanent fix:


See also

 


Keywords

 

OPI, RIP, file formats, output, plate, screening


Technical contact(s)
 

Stephen Zmetana

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.