Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 1.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
A CT/LW page with a high CT resolution (e.g. 1200 dpi) is converted to DCS using CEPSLink 2.5.2, refined, and output. A small hairline artifact is visible on high-resolution output. |
|
|
|
||
Cause |
||
|
|
||
Solution |
A) Refine using Bypass mode, or B) Refine without downsampling the CT resolution, or C) Convert the CT/LW page using CEPSLink 3.1. Permanent fix: Prinergy 2.0 |
|
|
|
||
See also |
||
|
|
||
Keywords |
CEPSLink, CT-LW Import, output |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
||
Date submitted |
||