Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Hairline artifact appears on CT/LW page


Product

  Prinergy 1.1

Platform

 

Operating system

 


Error

 


Symptoms

 

A CT/LW page with a high CT resolution (e.g. 1200 dpi) is converted to DCS using CEPSLink 2.5.2, refined, and output. A small hairline artifact is visible on high-resolution output.


Cause

 

Solution

 

A) Refine using Bypass mode, or

B) Refine without downsampling the CT resolution, or

C) Convert the CT/LW page using CEPSLink 3.1.

Permanent fix: Prinergy 2.0


See also

 


Keywords

 

CEPSLink, CT-LW Import, output


Technical contact(s)
 

James Bredenhof

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.