Error |
||
|
|
||
Symptoms |
A hairline runs across the width of the page. It may extend across the entire width of the page, or only a portion. The artifact is only visible at high resolutions. |
|
|
|
||
Cause |
The resolution of the linework does not match the resolution of the ouput device. When a linework file is created on a Brisque, it is created to a specified resolution. If this resolution does not match the resolution of the output device, artifacts may result. |
|
|
|
||
Solution |
1) Recreate the Brisque page with a linework resolution that matches that of the output device. 2) Re-refine the CT/LW page with linework resampling enabled in the process plan. Set the linework resolution to match the output device. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
CT-LW Import, output |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
||