Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Normalize with CEPSConversion fails if CEPSConversion JTP is on a secondary server. |
|
|
|
||
Cause |
This is a bug. It will be fixed in a subsequent Prinergy patch. | |
|
|
||
Solution |
Locate all CEPSConversion JTPs on the Primary server. Permanent fix: Prinergy 2.0 |
|
|
|
||
See also |
||
|
|
||
Keywords |
CT-LW Import, normalizer |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
||
Date submitted |
||