Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Some marks do not render properly in Prinergy (with no error message displayed) [ID: 81593]


Product

 

Kodak® Prinergy® 3.1.0.5 or later

Error

  None

Symptoms

  Marks such as $[LayoutName] or $[JobName], or some others, do not render when output in Prinergy.

Cause

  The Adobe™ RIP does not appear to be reading the marks file properly.

Solution

  To restore the previous method of handling marks, reset the registry on the server and restart Marks JTP as follows:
  1. Open Regedit.
  2. Locate software > Creo > Araxi > Default > MRKJ.
  3. Add a reg_dword to the marks registry key for MRKJ_WordFinderVersion and set its value to 2, or change the existing reg_dword value to 2.
  4. Restart the Marks JTP.

Technical contact(s)
 

Alex Marinets

Submitted by
 

Alex Marinets

Date submitted
 

12 Jul 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.