Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy stops responding during database backup on a Hot Standby server with the Double-Take software


Product

 
  • Kodak® Prinergy® 3.x, 4.x, with Hot Standby option
  • Double-Take®

Operating system

 

  • Microsoft® Windows® 2000
  • Microsoft Windows Server® 2003


Symptoms

 

The Prinergy system stops responding during backup of the Oracle® database. When Prinergy is restarted, the software may take more than 30 minutes to start up.

Both the Oracle backup and the Prinergy backup take a long time to complete. One customer reported that it took up to 21 hours for their backup to tape to finish.

Note: If you stop the Double-Take software or disconnect the PrinergyDB replication set, Prinergy responds normally during an Oracle backup, and the backup completes in a more reasonable time.

In the properties of the PrinergyDB replication set, the *.bck file is not excluded.


Cause

 

Older versions of the HotStandby installer included the *.bck files in the replication. The way that Oracle generates the *.bck files during replication causes the Double-Take software to slow down the system.


Solution

 

On the primary server, replace the PrinergyDB replication set with one that excludes the *.bck files from the replication.

Note: This problem is fixed in the HotStandby with Double-Take installer, 651-00325B Rev A or later.

  1. On the primary server, open the Double-Take Management Console.
  2. In the Management Console window, log on to the primary server and the failover server.
  3. Select the primary server.
  4. Disconnect the PrinergyDB replication set (repset).
  5. Delete the PrinergyDB replication set.
  6. Download the following scripts to the server desktop:
  7. Move the CreateRepset.cmd script to the Primary %ProgramFiles%\DoubleTake\Creo folder to replace the old version.
  8. Move the GetOraclePath.cmd script to the Primary %ProgramFiles%\DoubleTake\Creo\bin folder to replace the old version.
  9. Run the CreateRepset.cmd script to create the PrinergyDB replication set.
  10. In the Management Console window, connect the PrinergyDB replication set to start mirroring and replication.

Technical contact(s)
  Philip Samaniego
Submitted by
  Philip Samaniego
Date submitted
 

15 Aug 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.