Windows Firewall settings prevent Prinergy Workshop from starting on secondary servers and workstations


Product

  Kodak® Prinergy® 4.x

Platform

 

PC

Operating system

 

Microsoft® Windows Server® 2003 R2


Symptoms

  Prinergy runs normally, but Workshop will start only on the Prinergy primary server. Workshop responds after a timeout period that it is unable to determine the version of Prinergy. No system or network errors are detected.

Cause

  The Prinergy primary server is running the Windows Server 2003 R2 operating system with the Windows Firewall utility turned on. The port or ports that Workshop uses to make network connections to secondary servers and workstations are being blocked.

Solution

  Turn off Windows Firewall. Instruct the customer to use a hardware firewall instead.