Message "Process Template:" appears when adding a hot folder after a system rule set is enabled


Product

  Kodak® Prinergy® 3.1.0.6

Error

 

Process Template:
on the Manage Hot Folders for Job '???' dialog box.


Symptoms

 

When you create a job, enable a system rule set, and then create a hot folder to use that rule set, the error message appears.

Note: This problem only occurs with a system rule set.


Cause

 

This error occurs because of a problem in the Rules-Based Automation (RBA) code.


Solution

 

Upgrade to Prinergy 4.1.0.0 or later. The problem was fixed in Prinergy 4.1.0.0.


See also

 

PR #KBOE-1013


Keywords

 

Workshop, process templates, hot folders, RBA (automation)


Technical contact
 

Ken Boyle