Kodak® Prinergy® 3.1.0.6 | ||
Error |
|
||
Symptoms |
When you create a job, enable a system rule set, and then create a hot folder to use that rule set, the error message appears. Note: This problem only occurs with a system rule set. |
||
Cause |
This error occurs because of a problem in the Rules-Based Automation (RBA) code. |
||
Solution |
Upgrade to Prinergy 4.1.0.0 or later. The problem was fixed in Prinergy 4.1.0.0. |
||
See also |
PR #KBOE-1013 |
||
Keywords |
Workshop, process templates, hot folders, RBA (automation) |
||
Technical contact |
|||
Submitted by |
|||
Date submitted |
06 Nov 2007 |
||