Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Kodak® Prinergy® 4.0.2.1, build 53 |
||
Operating system |
Microsoft® Windows Server® 2003 |
||
Error |
|
||
Symptoms |
The Prinergy software fails to upgrade to version 4.0.2.1, and rolls back to the previous version. The error message appears. |
||
Cause |
The PPU is unable to locate the Rules-Based Automation(RBA) files on the render station because they are not installed. When it cannot locate them, it fails. |
||
Solution |
Copy the RBA files from the primary server to the render station.
Note: This problem will be fixed in a later build of 4.0.2.1. |
||
Keywords |
upgrade, PPU, RBA |
||
Technical contact(s) |
Amy Chan | ||
Submitted by |
Amy Chan | ||
Date submitted |
13 Dec 2007 |
||