Error |
E 18Dec07 15:01:37.578-CST [572.5464] JOHNSON ARAXI PMainDirectoryD iJKDR_RenameJobOpImpl.cpp(112): Unexpected error E 18Dec07 14:59:39.285-CST [000.000] prepress-4 greg workshop com.creo.araxi.USVW.USVW_eFatalIDL: Unrecoverable Corba error occurred |
||
Symptoms |
After renaming the Prinergy primary server, you start Prinergy Workshop and rename a job. Workshop quits and the error message appears. |
||
Cause |
When the Prinergy primary server was renamed, the location of the job server was not changed in the database. |
||
Solution |
Run the PChangeJobShare utility to update the database.
Note: Use upper-case letters for the server namesfor example, D:\> pchangejobshare -n JUPITER -o YCS9998-999
Note: When renaming a Prinergy primary server, you must also run the PChangeJobShare utility to update the new server name and share name and then run the Orbacusconfig-init utility to update the Orbacus database to the new name. For detailed instructions on how to rename a Prinergy server, see Renaming a Prinergy 4.x Server. |
||