Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Automation daemon restarts every 30 seconds, and then stops


Product

 

Kodak® Prinergy® Connect™, version 4.0.2.1


Symptoms

 

Every 30 seconds, the Automation daemon restarts, and then stops.


Cause

 

The Rules-Based Automation (RBA) configuration file is not written correctly. A text line is positioned outside the <appSettings> section.


Solution

 

Correct the configuration file:

  1. Locate C:\Program Files\Kodak\RBA\bin\.
  2. Using a text editor such as Notepad, open the AutomationApp.exe.config file.
  3. Locate the line: <add key=“MailServer” value=“1.1.1.1” />.
  4. Move the line so that it is positioned inside the <appSettings></appSettings> section.
  5. Save the file.


Keywords

 

RBA (automation), daemons


Technical contact(s)
  Ken Boyle
Submitted by
  Ken Boyle
Date submitted
 

10 Jan 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.