Prinergy Workshop fails when Preps is used to create an imposition for two different jobs


Product

 

  • Kodak® Prinergy® Connect™, version 4.0.2.x
  • Kodak Preps®

Operating system

 

Microsoft® Windows®


Error

 

assertion failure
at com.creo.araxi.UDBG.UDBG_Assert.IsTrue(UDBG_Assert.java:78)
at com.creo.araxi.UDBG.UDBG_Assert.IsTrue(UDBG_Assert.java:84)
at com.creo.araxi.UWSP.UWSP_BaseWorkshop.getSubPageElementDM(UWSP_BaseWorkshop.java:1686)
...


Symptoms

 

In Prinergy Workshop, you open a job and create a new imposition, using the Kodak Preps® digital imposition software. You then close that job, open a second job, and begin to create another new imposition using the Preps software. When the New Imposition Details dialog box appears, you click OK. Workshop closes unexpectedly.


Solution

 

Do not close the first Prinergy job before creating or editing an imposition for a second job.

Note: This problem is fixed in version 4.0.2.3.


PR #

 

JBRF 1265

Keywords

 

Workshop, Preps, imposition/layout


Technical contact(s)
  James Bredenhof
Submitted by
  James Bredenhof
Date submitted
 

29 Jan 2008