Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Rules-Based Automation must be reinstalled


Product

 

Kodak® Prinergy® Connect™, version 4.x

Operating system

 

  • Microsoft® Windows® 2000 Server
  • Microsoft Windows Server® 2003


Symptoms

 

Symptoms may include:

  • The PPU can't uninstall Rules-Based Automation (RBA) because files such as uninst.isu are missing.
  • RBA does not run. For example, diag log messages indicate failed restart attempts for AutomationApp.exe.
  • Prinergy Workshop shows Automation Status ... instead of Rule Set Manager.
  • Existing rule sets don't run.


Cause

 

The PPU upgrade failed.


Solution

 

Manually reinstall RBA by performing the steps in Reinstalling Rules-Based Automation.

This problem is expected to be fixed in Prinergy 5.0.


Keywords

 

RBA (automation), installation, upgrades


Technical contact(s)
  Ken Boyle
Submitted by
  Ken Boyle
Date submitted
 

29 Jan 2008