Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Task History not as detailed as it was previously (no longer reports which page had problems)


Product

 

Kodak® Prinergy® Connect™, version 4.0.2.2

Operating system

 

  • Microsoft® Windows® 2000 Server
  • Microsoft Windows Server® 2003


Symptoms

 

When an error occurs with multi-page input files, the Task History no longer reports which page had problems. For example, the Low Resolution image found on file error message is not as detailed as it was in earlier versions of Prinergy.


Cause

 

This is a known problem in Prinergy 4.0.2.2.


Solution

 

The workaround is to set HKEY_LOCAL_MACHINE\SOFTWARE\CREO\Araxi\Settings\Default\OPTI\< OptimizerName >\TerseHistoryMessages to 0 (zero).

This problem will be fixed in Prinergy 4.0.2.3.


Keywords

 

JTPs, registry, refiner, normalizer, optimizer


Technical contact(s)
  James Bredenhof
Submitted by
  James Bredenhof
Date submitted
 

18 Feb 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.