Symptoms |
During an upgrade from Prinergy 4.0.2.0 on a secondary server running Hot Standby (EPM+), the Prinergy Update Utility (PPU) fails and the error message appears. |
||
Cause |
The Hot Standby replicator service (VERITAS Storage Replicator software) is running and locking the Ora816 folder. This prevents the PPU from accessing the folder. |
||
Solution |
Manually stop the VERITAS Storage Replicator RSA service before the upgrade and restart it after the upgrade. |
||