Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Rules-Based Automation won't start


Product

 

Kodak® Prinergy® Connect™ version 4.x or later

Operating system

 

  • Microsoft® Windows® 2000 Server
  • Microsoft Windows Server® 2003


Error

 

W 21Feb08 13:39:35.094-EST [128728.1] ARAXI
AutomationApp MainApp.cs(300)
Creo.PWS.Automation.AutomationApp.MainApp():Unable to acquire remoting port, will retry for 10 seconds

E 21Feb08 13:39:45.094-EST [128728.1] ARAXI
AutomationApp MainApp.cs(303)
Creo.PWS.Automation.AutomationApp.MainApp():Exception message: Only one usage of each socket address (protocol/network address/port) is normally permitted


Symptoms

 

The error message appears in Diagview during Prinergy Connect startup. In Prinergy Workshop, you cannot open the RuleSet Manager.


Cause

 

The RuleUtility tool is not running correctly.


Solution

 

Open Task Manager, locate the RuleUtility.exe file, and end its process.

If the RuleUtility tool is the problem, the AutomationApp and WebServerApp utilities start, and you can open the RuleSet Manager in Prinergy Workshop.


Keywords

 

automation, RBA


Technical contact(s)
  Ken Boyle
Submitted by
  Ken Boyle
Date submitted
 

21 Feb 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.