Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Rules-Based Automation cannot process a Storefront schema


Product

 

  • Kodak® Prinergy® Connect™, version 4.0.2.2e
  • Kodak InSite™ Storefront

Operating system

 

  • Microsoft® Windows® 2000 Server
  • Microsoft Windows Server® 2003


Error

 

The invoked member is not supported in a dynamic assembly.


Symptoms

 

InSite Storefront schemas that use an XSLT (translation) fail, and the error message appears. In the Rule Set Builder, the ReadXML action is displayed in red because the action cannot find the specified schema.


Cause

 

A method name in Microsoft .NET Framework 2.0 has changed.


Solution

 

A drop-in file is available from the Response Center.

Note: This problem is fixed in Prinergy 4.0.2.3 or later.


Keywords

 

automation (RBA)


Technical contact(s)
  Ken Boyle
Submitted by
  Ken Boyle
Date submitted
 

04 Apr 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.