Symptoms |
After you open a job, Prinergy Workshop closes or stops responding. The error message appears in the diagnostic log files from one or more Prinergy server daemons. |
||
Cause |
There are two possible causes:
|
||
Solution |
First, determine the number of JTPs on the primary server. If the number seems large (25-plus), temporarily shut down a few JTPs to try and solve the problem. If that is the solution, redistribute JTPs to other servers, or remove them entirely (for example, very few sites require eight ColorMatch JTPs). If the problem persists, perform the following procedure.
If this does not solve the problem, there may be a corrupt job in the database. Note very carefully which jobs were open at the time of the problem, and test them one by one until you find the corrupt job. After you locate it, recreate the job from scratch. |
||