Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Oracle 10 installation error when using rehosting tool v2.1: The log file cannot be found


Product

 
  • Kodak® Prinergy® Connect™, version 4.0
  • Prinergy rehosting tool, version 2.1
  • Oracle® 10 software

Error

  The log file cannot be found.

Symptoms

  When you use the Prinergy rehosting tool version 2.1 to install the Oracle 10 software, the tool reports an error soon after starting the installation.

Cause

  The timeout period for the rehosting tool to wait for the Oracle installer to start is too short.

Solution

 

  1. In the PgyCfg-2.1 rehosting tool folder, locate the RHST_OracleInstall.py file.
  2. Using a text editor (for example, Notepad), edit the RHST_OracleInstall.py file as follows:
    Change line 41 from time.sleep(5) # just to be safe, delay checking for running process
    to
    time.sleep(10) # just to be safe, delay checking for running process.


Keywords

  installation, Oracle, rehosting

Technical contact
 

Amy Chan

Submitted by
 

Fabian Warkalla

Date submitted
  29 Apr 2008

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.