Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Kodak® Prinergy® Connect version 4.x |
||
Symptoms |
When you place a test file in the processplans folder and run the AraxiFileReplicator service, the file is not copied to the failover server. | ||
Cause |
The OriginalPrimaryNodeName value in the registry is configured with the name of a server that no longer exists. Note: The value is located in the registry at HKLM\software\creo\araxi\settings\default\system\. |
||
Solution |
Reconnect the failover server to the Prinergy system by running the ConfigEPServer script on the failover server.
Note: The -p switch is the primary server name, and the -l switch is the folder where the log file (ConfigEPServer.log) will be written.
Note: The ConfigEPServer.cmd file is located in the %AraxiHome%\CreoAraxi\ folder. |
||
Keywords |
EPM | ||
Technical contact |
|||
Submitted by |
|||
Date submitted |
29 Apr 2008 | ||