Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Tape retrieval fails with a medium missing message, but the tape is in the RSM database


Product

 

Kodak® Prinergy® Connect™ version 4.x


Error

  The Archive Medium xxxx is missing

Symptoms

 

When Prinergy Archiver tries to retrieve a job, the error message appears. The archive medium is listed in the Removable Storage Manager (RSM) with a status of Idle, Allocated, and you can run NTBackup successfully to retrieve the job and catalog the tape.


Cause

 

Two Archiver JTPs are configured, one on the primary server and one on the secondary server, and the tape library is configured on the secondary server.

Prinergy Archiver uses the archiver JTP on the primary server to locate the RSM database. Since the tape library is configured on the secondary server, Archiver does not find any tape.


Solution

 

  1. Remove the Archive/Retrieve JTP and Purge JTP on the primary server and the secondary server:
    1. On the primary server, start Prinergy Administrator.
    2. On the Processes tab, right-click the Archive/Retrieve JTP and select Remove JTP.
    3. On the Processes tab, right-click the Purge JTP and select Remove JTP.
    4. Repeat steps a-c on the secondary server.
  2. On the server where the tape library is configured, create an Archive/Retrieve JTP. On the Processes tab, select JTP > Add JTP > Archive/Retrieve.
  3. On the server where the tape library is configured, create a Purge JTP. On the Processes tab, select JTP > Add JTP > Purge.
  4. On the primary server, click the Processes tab and check that there is only one Archive/Retrieve JTP running and one Purge JTP running.

Keywords

  archiver, archiver-retrieve

Technical contact
 

Amy Chan

Submitted by
 

Amy Chan

Date submitted
  30 Apr 2008