Cannot copy jobs after rehosting a Prinergy system


Product

 

Kodak® Prinergy® Connect™ version 4.x


Component

 

Prinergy Primary Rehost Tool, earlier than version 2.1


Symptoms

 

After rehosting, you are unable to copy jobs.


Cause

 

The Copyjob process template did not migrate properly during rehosting.


Solution

 

Add the Copyjob process template to the director.ini file:

  1. On the primary server, locate \\Prinergy\AraxiHome\CreoAraxi\data\MetaData.
  2. Open the director.ini file in Notepad.
  3. Add CopyJob to the Import/Export category:
  4. [Categories.ImportExport]
    CategoryName = Import/Export
    CategoryGUID = 6c2a9817f5af7dd97dc7c15d2f3a02a3
    CodedNameNum = 1046200

    ProcessPlanTypes = Import, Export, CopyJob

  5. Save the director.ini file.
  6. In Prinergy Administrator, on the Processes tab, stop Process Plan Daemon (PTaskTemplate.exe).
    Note: Ensure that no one is editing a process template before you stop the daemon.
  7. In Prinergy Workshop, select Tools > Process Template Editor, and try to open some process templates.

  8. The Process Plan daemon starts.
  9. Quit and restart Workshop.

This problem is fixed in the Prinergy Primary Rehost Tool version 2.1.