Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
All versions of Kodak® Prinergy® Evo |
|
|
|
||
Error |
Prinergy Evo cannot start due to an invalid IP address in the Orbacus database. Prinergy Evo uses various socket-based communication technologies, including CORBA (Common Object Request Broker Architecture). The CORBA implementation used by Prinergy Evo is Orbacus. CORBA allows applications to communicate with each other, regardless of where they are located or who designed them. |
|
|
|
||
Symptoms |
Prinergy Evo will not start on a system where the Prinergy software is or was previously installed. |
|
|
|
||
Cause |
An incompatible registry key between Kodak Prinergy® software and Prinergy Evo. | |
|
|
||
Solution |
If this is a Prinergy Evo server stand-alone, then remove the OOC keys in the registry under HKEY_LOCAL_MACHINE \SOFTWARE\OOC. If Prinergy Evo is installed on a Prinergy Connect primary server, then Prinergy Evo 4.0.6.5 and later and Prinergy Connect 4.0.2.2 and later have been qualified to run on the same server. Earlier versions are not qualified and may not work. Perform the following instructions on the primary server:
If the Prinergy Connect server is a secondary or renderstation, then Prinergy Evo 3.0.6.5 and Prinergy Connect 3.1.0.3 are the minimum qualified versions.
|
|
|
|
||
Technical contact(s) |
||
Submitted by |
||
Date submitted |
30 March 2006 |
|